User Manual
Central Terminal Level Control Unit
Operators Manual
GSI 002
605-0000-428
Issue 1.2. Date 5/11/98
Page 10 of 14
6.7. Configuration Information Menu
This menu displays: Current Shelf Id, PN code, RW Code RF channel number
and Mode. This menu cannot be used to alter any of the displayed parameters.
Config SH:2 0--
PN: # RW:## 0--
RF: ## PL:##.# ---
Mode: **** ---
PN Code No
RF Channel
Shelf Operating
Mode
RW code
Path Loss
(dB)
6.8. Error Information Menu
This menu will display the error status for the given shelf.. The ‘*’ next to the
error type indicates that error has occurred .
Error SH:1 0E-
Comms * Conv 0--
Sh Id Det ---
CRC Modem ---
Communications time-out error
Incorrect shelf identifier in the
received data packet
Incorrect CRC checksum in the
received data packet
Failed to converge within 15 mins
(applicable only to poll modes)
RF failure in LCU
Failed to enable the modem
associated with the RW
6.9. LCU Configuration Set-up Selection Menu
The LCU configuration information is divided into: Calibration Mode and Path
Loss Information. This menu displays the current shelf identifier.
Shelf : 1 0E-
>Mode Select< 1-R
Path Loss Set 0--
CT RX Trim ---
6.10. Mode Select Menu
This menu is used to select any one of the available modes. The available
calibration modes are: Continuous 1 hour, 1 day, idle or none. The continuous