User Manual
AS4000 Subscriber Terminal
Installation and Commissioning DLP 012
605-0000-436
Issue 1.5 Date: 18th October 1999
Page 1 of 2 1988 Airspan Communications Corporation
BATTERY CONNECTION FOR TYPE 2 AND TYPE 4
PSUs.
Do not connect the battery until the commencement of commissioning
Note if the Type 2/4 PSU is used for D128 do not use batteries to ensure sufficient
voltage is present at CRU
STEP PROCEDURE
1. Remove PSU cover and disconnect cover earthing lead if connected.
2. Place the spade connectors onto the battery terminals in the following order:
a) Blue leads to centre positive and -ve terminals
b) Black lead to -ve terminal (Right hand battery)
c) Red lead to +ve Terminal
+ +- -
BLUE BLUE BLACKRED
3. Press SW3 and ensure green Power OK LED is illuminated
STOP. THIS PROCEDURE HAS BEEN COMPLETED.