User Manual
AS4000 Subscriber Terminal
Installation and Commissioning DLP 011
605-0000-436
Issue 1.5 Date: 18th October 1999
Page 4 of 8
8. Figure 35 below, illustrates the connections of the drop cable to the connector
blocks inside the Junction Box. The diagram shows the order of wire insertion to
ensure that the cables fit in the junction box. When connecting the thick stranded
wire ensure that the screws are fully undone and the hole fully opened to allow the
wire to be inserted without displacing strands. A wire loop should be inserted
between tags 3 & 4.
9. Run and connect the cable from the NTU to the Junction Box. The VF wires are
connected to the same Tags as the wires from the CRU. Run and connect the cable
from the PSU to the Junction Box.
10. When wiring is complete re-insert the circuit board into the box and secure the
cables with tie wraps.
DC Output
Cable from
AC PSU
To
STMON
Cable from CRU
JACK
SOCKET
7
8
9
10
11
12
6
5
4
3
2
1
Cable from
RJ45
♦
Note:Tags 3& 4 should be looped with a single strand wire.
Tag Function
1 UpLink Comms
2 Down Link Comms
3
♦ Logic 0V
4 ♦ Logic 0V
5 Batt Pos DC Volts
6 Batt Neg DC Volts
7 ST RX+
8 ST RX-
9 Not Connected
10 ST TX+
11 ST TX -
12 Batt Pos DC Volts
Colour
NTU
CRU Cable PSU 30V brick
Grey
Yellow
Thin Black & Screen
Outer Braid
Thick Red
Thick Black
Violet VF1A
Orange VF1B
Blue VF2A
White VF2B
White
Figure 35. Drop Cable Connections to Junction Box.