User Manual

AS4000 Subscriber Terminal
Installation and Commissioning DLP 011
605-0000-436
Issue 1.5 Date: 18th October 1999
Page 3 of 8
Six Pair Drop Cable Termination at the PSU (Type 1 only)
1. Run cable end into the Junction Box. Estimate the length of end required for
termination of wires (allow 150mm of conductor for a maintenance re-termination
of wires) and cut cable to length.
2. Strip outer cable sheath using a knife or cable stripping tool to expose wires.
3. Strip and terminate the wires of the drop cable as shown in Figure 34.
Yellow 25 mm
Grey 25 mm
Black 50 mm
Thick Black 50 mm
Thick
Red
40 mm
White
45 mm Blue
45 mm
Violet
50 mm
Orange
50 mm
Screen
40 mm
Green, Brown and Strain
wires should be cut off neatly
to the Butt of the cable
All wires should be have 5mm
of insulation stripped
Cut wires to lengths shown
Stranded wires
should be
tightly twisted
Figure 34. Wire Striping Dimensions for 80 Metre Drop Cable Lead-Out