User Manual
AS4000 Subscriber Terminal
Installation and Commissioning DLP 011
605-0000-436
Issue 1.5 Date: 18th October 1999
Page 1 of 8 1988 Airspan Communications Corporation
CABLE TERMINATION FOR ST-I1.
STEP PROCEDURE
Drop Cable Connector
1. Important Notice: Care should be taken when plugging the drop cable into the
connector on the rear plate of the CRU. The cable approaches the socket from
above. The cable socket has a polarisation key and the plug has a polarisation slot
to ensure that the connectors mate correctly. Support the cable so that the plug
does not connect to the socket at an angle. The plug must be eased into the socket
ensuring the polarisation key locates. Damage to the pins may result if the pins are
not inserted straight into the sockets or the polarisation key is not located
correctly. Ensure that the pins are fully mated before attempting to tighten the
locking ring. Tighten the locking ring using the fingers. Do not use a wrench as
over-tightening will strip the thread on the locking ring.
1 Not Used
2 AGC Mon (Outer)
3 PC Mon (Outer)
4 24V + DC
5 0V - DC
6 Downlink Comms
7 Uplink Comms
8 SRX+
9 SRX-
10 STX+
11 STX-
12 0V Drain/Screen
Polarisation Key
1
9
8
7
6
5
4
3
2
11
10
12
Figure 32. Drop Cable Connector Plug