User Manual

AS4000 Subscriber Terminal
Installation and Commissioning DLP 010
605-0000-436
Issue 1.5 Date: 18th October 1999
Page 6 of 8
Drop Cable Termination at the PSU (Type 4A only)
1. Run cable end into the PSU. Estimate the length of end required for termination of
wires (allow 150mm of conductor for a maintenance re-termination of wires) and
cut cable to length.
2. Strip outer cable sheath using a knife or cable stripping tool to expose 150mm of
conductor, leaving sufficient length to allow the cable retaining clip to grip the
sheath.
3. At the PSU terminate the wires of the drop cable with the red insulated terminal
pins and screw to the terminal blocks(TB1 & TB2). Table 12 illustrates the
connections of the drop cable to the connector blocks inside the AC PSU.
PCB Function 25 Metre 80 Metre RJ45
TB1 Connector Belden (Grey) (Black)
1 Wago V+ to CRU White with grey stripe Red (thick
multistrand)
2a Connectors 0V to CRU Grey with white stripe Black (thick
multistrand)
2b 0V to CRU
3 Screen from Drop-cable Tinned Tinned Drain
Wire
4 IDC Up-Link (RS232-TX) Brown with white stripe Grey
5 Down-Link (RS232-RX) White with brown stripe Yellow
6 Power Control Green with white stripe Brown
7 AGC White with green stripe Green
8 Drop-cable 12
th
wire Blue with red stripe Red (thin)
9 0V Logic Red with blue stripe Black (thin)
10
φ 0V Logic Ref
Link to TB1 11 Link to TB1 11
11
]note 3
0V to CRU Link to TB1 10 Link to TB1 10
TB2
1 VF Data 2Mbit/sTX Twisted
2 OUT 2Mbit/sTX pair 1
3 IDC 2Mbit/sRX Twisted
4 2Mbit/sRX pair 2
5 VF Data 2Mbit/sTX White with blue stripe Violet
6 IN 2Mbit/sTX Blue with white stripe Orange
7 IDC 2Mbit/sRX White with orange stripe Blue
8 2Mbit/sRX Orange with white stripe White
Table 12 Type 4A PSU terminations
φ Note 2: TB1/10 is used as a 0 Volt reference when measuring PC and AGC.
] Note 3: Link to TB1 10 to TB1 11 using wire offcut.