User Manual

AS4000 Subscriber Terminal
Installation and Commissioning DLP 010
605-0000-436
Issue 1.5 Date: 18th October 1999
Page 4 of 8
5. Figure 27 below, illustrates the connections of the drop cable to the connector
blocks inside the Junction Box. Figure 28 shows the order of wire insertion to
ensure that the cables fit in the junction box. When connecting the thick stranded
wire ensure that the screws are fully undone and the hole fully opened to allow the
wire to be inserted without displacing strands. A wire loop should be inserted
between tags 3 & 4.
6. Run and connect the cable from the RJ45 to the Junction Box. The TX and RX
wires are connected to the same Tags as the wires from the CRU. Run and connect
the cable from the PSU to the Junction Box.
7. When wiring is complete re-insert the circuit board into the box and secure the
cables with tie wraps.
DC Output
Cable from
AC PSU
To
STMON
Cable from CRU
JACK
SOCKET
7
8
9
10
11
12
6
5
4
3
2
1
Cable from
RJ45
Note:Tags 3& 4 should be looped with a single strand wire.
Colour
80 metre (Black Sheath)
Grey
Yellow
Thin Black & Screen
Thick Red
Thick Black
Violet
Orange
Blue
White
PSU 30V brick
Outer Braid
White
RJ45
Outer Braid
TX 2Mbit/s
TX 2Mbit/s
RX 2Mbit/s
RX 2Mbit/s
25mBelden (Grey Sheath)
Brown with white stripe
White with brown stripe
Red with blue stripe & Screen
White with grey stripe
Grey with white stripe
White with blue stripe
Blue with white stripe
White with orange stripe
Orange with white stripe
Tag
1
2
3
4
5
6
7
8
9
10
11
12
Function
UpLink Comms
Down Link Comms
Logic 0V
Logic 0V
Batt Pos DC Volts
Batt Neg DC Volts
TX 2Mbit/s
TX 2Mbit/s
Not Connected
RX 2Mbit/s
RX 2Mbit/s
Batt Pos DC Volts
Figure 27. Drop Cable Connections to Junction Box.
Pin
1
2
3
4
5
6
7
8
9
10
11
12
Function
UpLink Comms
Down Link Comms
Logic 0V
Batt Pos DC Volts
Ground
Batt Neg DC Volts
TX 2Mbit/s
TX 2Mbit/s
Not Connected
RX 2Mbit/s
RX 2Mbit/s
Ground
Colour
Brown with white stripe
White with brown stripe
Red with blue stripe
White with grey stripe
Grey with white stripe
White with blue stripe
Blue with white stripe
White with orange stripe
Orange with white stripe
Screen
JACK
SOCKET
1
2
3
4
5
6
12
11
10
9
8
7
Figure 28 Drop Cable Connections to Junction Box. Before Dec 1998