User Manual
AS4000 Subscriber Terminal
Installation and Commissioning DLP 010
605-0000-436
Issue 1.5 Date: 18th October 1999
Page 3 of 8
Drop Cable Termination At Junction Box. (type 1 PSU)
1. Note Wiring of the junction Box may differ if wired prior to December 1998
2. Run the drop cable from the CRU connector block to the Junction Box. Secure the
junction box housing to the wall in the required position with two screws.
3. Remove the junction box circuit board from the housing held in position by one
plastic retaining clip on each side.
4. Make sure that the free end of the drop cable reaches the junction box housing.
Mark and cut to length and tailor the wire ends as shown in Figure 26.
Yellow 25 mm
Grey 25 mm
Black 50 mm
Thick Black 50 mm
Thick
Red
40 mm
White
45 mm Blue
45 mm
Violet
50 mm
Orange
50 mm
Screen
40 mm
Green, Brown and Strain
wires should be cut off neatly
to the Butt of the cable
All wires should be have 5mm
of insulation stripped
Cut wires to lengths shown
Stranded wires
should be
tightly twisted
Figure 26. Wire Striping Dimensions for 80 Metre Drop Cable Lead-Out