User Manual
AS4000 Subscriber Terminal
Installation and Commissioning DLP 010
605-0000-436
Issue 1.5 Date: 18th October 1999
Page 1 of 8 1988 Airspan Communications Corporation
CABLE TERMINATION FOR ST-D128 WHEN USING
TYPE 1 & TYPE 4A PSU.
STEP PROCEDURE
Drop Cable Termination at CRU.
Important Notice: Care should be taken when plugging the drop cable into the
connector on the rear plate of the CRU. The cable approaches the socket from above.
The cable socket has a polarisation key and the plug has a polarisation slot to ensure
that the connectors mate correctly. Support the cable so that the plug does not connect
to the socket at an angle. The plug must be eased into the socket ensuring the
polarisation key locates. Damage to the pins may result if the pins are not inserted
straight into the sockets or the polarisation key is not located correctly. Ensure that the
pins are fully mated before attempting to tighten the locking ring. Tighten the locking
ring using the fingers. Do not use a wrench as over-tightening will strip the thread on
the locking ring.
1. Table 11 below, details the 12 way CRU connector block showing pin number,
function, limits, description and colour drop cable conductors.
1 Logic 0 volts
2 AGC Mon
3 PC Mon
4 + DC supply
5 0V - DC supply
6 Downlink Comms
7 Uplink Comms
8 2Mbit/s TX
9 2Mbit/s TX
10 2Mbit/s RX
11 2Mbit/s RX
12 0V Drain/Screen
Polarisation Key
1
2
3
4
5
6
7
8
9
10
11
12
Figure 25. CRU Drop cable connector