User Manual
AS4000 Subscriber Terminal
Installation and Commissioning DLP 009
605-0000-436
Issue 1.5 Date: 18th October 1999
Page 10 of 10
TB2
1 2 3 4 5 6 7 8
1 2a 2b 3
TB1
4 5 6 7
8 9 10 11
1 2 3
ST
MON
Violet
Orange
White
Blue
Red
Black
Drain
Grey
Yellow
Green
Brown
Loop
5 Pair Drop Cable 6 Pair Drop Cable
TB2
1 2 3 4 5 6 7 8
1 2a 2b 3
TB1
4 5 6 7
8 9 10 11
1 2 3
ST
MON
Violet
Orange
White
Blue
Red
thick
Black
thick
Drain
Grey
Yellow
Green
Brown
Loop
Red
thin
Black
thin
Termination of NTUs
1. Run the NTU cable (2 wire) from NTU to the Junction Box, securing with 4mm
cleats as required and terminate as detailed in Table 10.
Function NTU PSU Type 1
Junction Box
Termination
PSU Type 2
Terminal Block
Terminations
PSU Type 4
Terminal Block
Terminations
VF1A NTU1 11 TB2 terminal 5 TB2 terminal 1
VF1B NTU1 10 TB2 terminal 6 TB2 terminal 2
VF2A NTU2 8 TB2 terminal 7 TB2 terminal 3
VF2B NTU2 7 TB2 terminal 8 TB2 terminal 4
Table 10. NTU Terminations for ST-V2
STOP. THIS PROCEDURE HAS BEEN COMPLETED.