User Manual

AS4000 Subscriber Terminal
Installation and Commissioning DLP 009
605-0000-436
Issue 1.5 Date: 18th October 1999
Page 6 of 10
Drop Cable Termination at the PSU (Type 2 only)
1. Run cable end into the PSU. Estimate the length of end required for termination of
wires (allow 150mm of conductor for a maintenance re-termination of wires) and
cut cable to length.
2. Strip outer cable sheath using a knife or cable stripping tool to expose 150mm of
conductor, leaving sufficient length to allow the cable retaining clip to grip the
sheath.
3. At the PSU terminate the wires of the drop cable with the red insulated terminal
pins and screw to the terminal blocks(TB1 & TB2). Figure 23 below, illustrates the
connections of the drop cable to the connector blocks inside the AC PSU.
VF1A
VF1B
VF2A
VF2B
VIO
ORA
BLU
WHI
RED
BLK
SCR
GRY
YEL
TO NTUs
FROM CRU
VF1A
VF1B
VF2A
VF2B
+VDC
0VDC
SCR
UPLINK
DOWNLINK
TB1TB2
TYPE 2 PSU Connector Detail
1234512345678
Figure 23. ST-V2 Drop Cable Connections to AC PSU (Type 2)