User Manual
AS4000 Subscriber Terminal
Installation and Commissioning DLP 006
605-0000-436
Issue 1.5 Date: 18th October 1999
Page 2 of 4
2. Install the Type 4A PSU within 2 metres of an AC power point and 25 metres of
the CRU. (80 metres if using cabling to pole mount for CRU).
3. Remove the PSU front cover. Offer the PSU up into position and mark the three
fixing positions onto the wall. (See Figure 12).
4. Drill the 3 holes, 8mm. diameter to a depth of 50mm. (use a depth gauge) and then
fit the FUB x 50mm Wall Plugs (Part No 128-0000-123) provided.
5. Secure the PSU squarely in position using the No 8 x 50mm screws (Part No 174-
0815-002) and cup washers (Part No 192-0080-230) provided.
Earth Stud
AC/DC
Converter
Mains IEC Inlet
Grommets
TB2
VF/Data INVF/ Data OUT
1 2 3 4 5 6 7 8
1 2a 2b 3
TB1
4 5 6 7
8 9 10 11
PC AGC
1 2 3
ST
MON
0V
Figure 16. Type 4A Power Supply Unit.
STEP PROCEDURE
AC Power Cord Installation
1. Use a supply cord fitted with a mains plug in accordance with local requirements.
Plug the AC supply cord into the IEC connector on the Type-4 PSU and secure
with retaining clip.
Note. Do not connect the plug to the supply socket until instructed to by the
Commissioning Test Procedure.