INSTALLING THE TYPE-4 PSU.
The Type 4 PSU consists of an PSU Unit with standby batteries and generates
power fail alarms that are passed to the CT.
STEP PROCEDURE
PSU (Type 4) Positioning and Securing
1. Confirm the position of the Type-4 PSU, allow for adequate ventilation and service
access.
2. Note: The life of the batteries within the Type-4 PSU will be increased in a low
temperature, but standby time will be improved by a warm environment. Ideally the
location should be cool, as the electronics within the unit will keep it warm enough
to ensure a good standby period.
250mm
Fixing Centres
150mm
Fixing Centres
75mm
Screw No 8
x 50mm
Wall Plug
FUB x 50mm
Cup
Washer
180mm
300mm
80mm
Figure 12. PSU Positioning and Securing