User Manual
AS4000 Subscriber Terminal
Installation and Commissioning DLP 004
605-0000-436
Issue 1.5 Date: 18th October 1999
Page 3 of 4
STEP PROCEDURE
AC Power Cord Installation
1. Use a supply cord fitted with a mains plug in accordance with local requirements.
Plug the AC supply cord into the IEC connector on the ACPSU and secure with
retaining clip.
Note. Do not connect the plug to the supply socket until instructed to by the
Commissioning Test Procedure.
2. Fit the cover to the PSU without securing the screws until instructed to by the
Commissioning Test Procedure.
PSU earthing
1. Note: The ACPSU is double insulated. It still has a 3-pin IEC socket and
therefore uses a 3-wire cable and mains plug. There is no earth wire connected to
the IEC socket inside the unit.
Hazardous Voltage Test Earth
If the hazardous voltage test is to be made functional then an additional earth has to be
run from a know good domestic earth and terminated to the 0V (Type 2 TB1 terminal
4)
STOP. THIS PROCEDURE HAS BEEN COMPLETED.
Safety: Battery Handling
Care should be taken when handling lead acid batteries to avoid
dropping or short circuiting them. Disposal should be in line with local
codes. Batteries may explode if put into a fire. Install the batteries in the
AC PSU first, then connect them taking care to observe correct
polarity.
Connect the blue lead first to connect them together, then connect the
red lead to the +ve terminal and the black lead to the -ve terminal.