User Manual

AS4000 Subscriber Terminal
Installation and Commissioning DLP 004
605-0000-436
Issue 1.5 Date: 18th October 1999
Page 2 of 4
3. Install the ACPSU within 2 metres of an AC power point and 25 metres of the
CRU.
4. Mark the wall fixing positions using the drilling template supplied. The ACPSU
should be fitted with the batteries towards the top and the mains input connector at
the bottom. (See Figure 10).
5. Drill the 4 holes, 8mm. diameter to a depth of 50mm. (use a depth gauge) and then
fit the FUB x 50mm Wall Plugs (Part No 128-0000-123) provided.
6. Remove the ACPSU front cover and install the batteries.
Note: Do not connect the batteries until instructed to do so at the commissioning
stage.
7. Secure the ACPSU squarely in position using the No 8 x 50mm screws (Part No
174-0815-002) and cup washers (Part No 192-0080-230) provided.
BATTERY BATTERY
TRANSFORMER
CONNECTOR
SW3
SW4
D9
D8
LEDs
AC
I/P
Figure 11. AC Power Supply Unit.