5. Using the wall bracket as a template, mark the first hole position. Where the CRU is to
be mounted to a brick built building, try to ensure that each hole coincides with the
middle of a brick and not the mortar course.
6. Drill the first hole, 10mm diameter to a maximum depth of 70mm (use a drilling depth
gauge) and then fit the Type S10 Wall Plug (Part No 128-0000-122) provided.
7. Using one of the wood screws M8 x 70mm (Part No 175-0008-006) and Plain Washers
(Part No 192-9000-033) provided, secure the CRU wall bracket section of the
mounting assembly to the wall.
8. Using a spirit level, adjust the position of the wall bracket and mark the remaining 3
holes.
9. Drill the remaining holes, 10mm diameter to a maximum depth of 70mm, then fit the
Type S10 Wall plugs (Part No 128-0000-122) provided.
10. Using the wood screws (Part No 175-0008-006) provided, secure firmly the CRU wall
bracket section of the mounting assembly to the wall.
Ariel view showing CRU
hinged from right
Ariel view showing CRU
hinged from left
Left or Right hinge should be chosen to facilitate
panning in the direction of the CT Antenna
Figure 6. CRU Hinge Position