Electrical Type 2 PSU (ACPSU)
AC Input Voltage: Range, 110VAC or 240VAC - Two Models.
Operating Range: 230V +/-10%. = 207V to 253V.
110V +6% -10%. / 99V to 116.6V.
Frequency: 48 to 63 Hz.
AC Input Fuse: 1 Amp - HBC[T] 5 x 20mm.
Nominal Output Voltage: 36V DC With mains present or +24V DC on battery
Min Voltage required at CRU:
connector block: ST-V2 18V
ST-D128 24V Can only be used without batteries.
ST-I1 18V
Power Consumption: 15 Watts
Overload Protection Fuse: 3.15 Amp, [T] 5 x 20mm.
Low Volts Alarm: Approx. 21V DC.
Standby Battery: 2 x Panasonic LCR 12V3.4P 12V3.4 Ah Sealed lead
acid. Standby duration approximately 3 hours
Electrical Type 4 PSU
AC Input Voltage: Range, 100VAC to 250VAC .
Operating Range: +6% -10%. / 90VAC to 265VAC.
Frequency: 45 to 65 Hz.
AC Input Fuse: 1 Amp - HBC[T] 5 x 20mm.
Nominal Output Voltage: 36V DC With mains present or +24V DC on battery
Min Voltage required at CRU:
connector block: ST-V2 18V
ST-D128 24V Can only be used without batteries.
ST-I1 18V
Power Consumption: 16 Watts normal
23 Watts Ringing
Overload Protection Fuse: 3.15 Amp, [T] 5 x 20mm.
Battery Fusing Resetable Fuse (PTC)
Low Volts Alarm: Approx. 21V DC.
Standby Battery: 2 x Panasonic LCR 12V3.4P 12V3.4 Ah Sealed lead
acid. Standby duration approximately 3 hours
Electrical Type 4A PSU
AC Input Voltage: 90 - 265 VAC
Operating Range: +6% -10%. / 100VAC to 250VAC.
Frequency: 45 to 65 Hz.
AC Input Max Current: 1 Amp .
Nominal Output Voltage: 40V ±1V
Power Consumption: 16 Watts normal (400mA@40V)
23 Watts Ringing (580mA@40V)
Ring Enable (1.8A peak)