User Manual
AS4000 Subscriber Terminal
Installation and Commissioning
DLP 002
605-0000-454
Draft Issue 1.3 Date 8/02/00
Page 5 of 6
2. Secure the Antenna Radium (with extension if fitted) to the Antenna mounting
bracket using four M6*20mm Hex Head Set Screws, 6mm Flat and 6mm Coiled
Washers as shown in Figure 17. Tighten the Set Screws to a torque of 4Nm.
3. Join the two halves of the bracket together using a bolt, spring washer, and plain
washer to top and bottom pivots.
M6 Plain Washer
M6 Coil Washer
M6 Set Screw
Ground for Lightning
Protection
M8 Pivot Bolt
M8 Plain Washer
M8 Coil Washer
M8 x 50mm screw and plain washer
or
M6 x 45mm Dyna Bolt
Figure 19. Wall Mounted Antenna (used for T6 cable)
4. Rotate the Antenna to face in the general direction of the CT. At this stage, only
finger tighten the pivot bolts.
2. Lightning Protection
1. When the antenna is attached to two / three floor dwellings lightning protection
should not be needed. If the Antenna is situated in an exposed position i.e on the top
of a multi-storey building the antenna should be grounded.
2. Run a 6mm stranded copper cable from the Antenna to a protection earth point i.e
building earth halo or earth provided specifically for lightning protection.
3. Secure the cable to the pole using straps and cleats as required
4. Fit a 6mm lug to the cable at the antenna end. Attach to the pole mount bracket
using the lower right M6 set screw as shown in Figure 20.
5. Connect to the earth point in accordance with local practice.