User's Manual

Installation
71
Type 7 PSU
Type 7 PSU s an auto-ranging basic power supply with battery back-up facility
The 7A PSU is an auto-ranging power supply with battery back-up facility. Release 7.15
supports only a 7Ah battery. Connection to the SIU is made using an integral co-axial lead
and D-Type plug connector. LEDs on the PSU indicate the following conditions:
PSU State LED 1
(Green)
LED 2
(Amber)
Connector
O/P
Normal
operation
On Off +V out
Mains fail Off On +V out
Mains &
batteryFail
Off Off 0V
The Type-7A can only be used with ST’s that have a 15-way D-type connector.
The 7B PSU is an auto-ranging power supply with battery back-up facility with extended
backup times
Note: Ensure a good power supply for the ST: PSUs have been connected to intermittent
supplies before, e.g. central heating timers. This will shorten the battery life (if fitted)
considerably as it is not designed to be constantly charged and discharged.
PSU (Type 7) Positioning and Securing
STEP PROCEDURE
1. Confirm the position of the Type-7 PSU, allow for adequate ventilation and service access.
Note: The life of the battery within the Type-7 PSU will be increased in a low temperature, but
standby time is improved in a warm environment. Ideally the location should be cool, as the
electronics within the unit will keep it warm enough to ensure a good standby period.
Warning: High voltages exist inside the product do not remove the cover to the main
electronics: No user serviceable parts inside.