User's Manual
Installation
69
Drop Cable Termination using RG11 Snap and Seal
Connectors
1. Place cable into jaws of the stripper tool (if at outdoor unit end place sealing boot over the
cable first).
2. Rotate tool 4 turns clockwise then 2 turns anti-clockwise
3. Grasp tool firmly and pull cable from the tool to expose braid and centre conductor.
4. A) Fold back braid over the jacket.
B) insert cable firmly into the connector as far as possible.
5. Place connector in activator tool and turn spindle to a positive stop.
6. Remove cable from the activator tool.