User's Manual
605-0000-595 Subscriber Terminal Installation and Commissioning
66
Drop Cable Termination Using Crimp Type Connectors
Termination of 6 series drop cable
1. If at the antenna end of the drop cable place a rubber boot over the end of the cable.
The boot is not required at the SIU.
2. Strip the drop cable using a knife or cable stripping tool to the dimensions shown
below.
3. Place the connector over the cable end ensuring that the inner sleeve passes
between the inner core and screen braid
4. Crimp the connector using the RG6 round crimp tool contained in the ST installation
tool box or a Amphenol 531-CR596R crimp tool.
Terminating F-Type Connectors to 6 Series cable
Termination of 11 series drop cable
1. If at the outdoor unit end of the drop cable place a rubber boot over the end of the
cable. The boot is not required at the SIU.
2. Strip the drop cable using a knife or cable stripping tool to the dimensions shown in
figure below
3. Fold back the braid against the cable sheath.
4. Ensure that the centre conductor is clean of dielectric residue. Push the crimp pin
over the end of the centre conductor until the pin bottoms against the dielectric, then
crimp the pin to the centre conductor with the 0.96 Hex crimp on the.RG11 hexagonal
crimp tool contained in the ST installation tool box.
5. Insert the cable into the connector ensuring the pin is through the hole of the insulator
at the bottom of the nut. Continue inserting the cable into the connector until it
bottoms out. Crimp the connector with the 0.475 hex crimp to retain the cable.