User's Manual

605-0000-595 Subscriber Terminal Installation and Commissioning
60
Installing the IF Unit for External Antenna
Use this procedure to install the IF unit when attaching an external antenna (usually not
supplied by Airspan). These antennas are used when a) additional gain is required to
increase system range. or b) improved isolation to interference is required by narrowing
antenna beamwidths. The mounting pole is not an Airspan supplied item and the pole should
be manufactured to suit local requirements. Before installing the antenna check that the
proposed position meets the site selection guidelines.
Country Specific Requirements
USA: In the USA the antenna shall be installed in accordance with articles 725, 800, 810 and
820 of the National Electrical Code
Canada: In Canada the antenna shall be installed in accordance with section 54 of the
Canadian Electrical Code
External antenna specific requirements
Impedance = 50ohms
Outdoor unit connector type = N-type
VSWR (max) =1.5:1
Signal power (max) = 200mw
The IF unit mounting kit comprises:
IF Unit
Item Quantity
Pole Bracket 1
M6 x 50mm Bolts 4
M6 Coiled Washer 4
M6 Plain Washer 4
Rubber Boot 2
Cable Tie 3
IF Unit Positioning and Securing.
STEP PROCEDURE
1. Confirm the position of the antenna ensuring that there is no obstruction in front and
to either side.
2. When multiple STs are deployed at the same site the recommended minimum
spacing between each antenna is 1 metre.
3. The antenna mounting pole should be fixed so that antenna panning can take place
in the horizontal plane and check that line of sight with CT antenna does not breach
the deployment rules. The antenna mounting pole is locally provided and should be
38mm or 1.5" in diameter. The pole should be fixed according to the pole
manufacturers’ instructions.
4. Note: Leave adequate clearance around the antenna assembly to allow for the full
adjustment range when aligning the antenna.
5. Secure the IF unit to the mounting bracket using the pole bracket secured by four
M6*50mm hex head set screws, 6mm flat, and 6mm coiled washers as shown in the
figure below. Tighten the set screws to a torque of 1.75Nm