User's Manual
Installation
57
Installing The Pole Mount Outdoor Unit .
Use this procedure to install the outdoor unit. The mounting pole is not an Airspan supplied
item and the pole should be manufactured to suit local requirements. Before installing the
outdoor unit check that the proposed position meets the site selection guidelines.
Country Specific Requirements
USA: In the USA the outdoor unit shall be installed in accordance with articles 725, 800, 810
and 820 of the National Electrical Code
Canada: In Canada the outdoor unit shall be installed in accordance with section 54 of the
Canadian Electrical Code
The Pole Mounting Kit comprises:
Item Quantity
Ooutdoor Unit Bracket 1
Pole Bracket 1
M6 x 50mm Bolts or M6 x 60mm Bolts 4
M6 Coiled Washer 4
M6 Plain Washer 4
Cable Tie 3
Outdoor Unit Positioning and Securing .
STEP PROCEDURE
1. Confirm the position of the outdoor unit ensuring that there is no obstruction in front
and to either side.
2. When multiple STs are deployed at the same site the recommended minimum
spacing between each outdoor unit is 1 metre.
3. The outdoor unit mounting pole should be fixed so that outdoor unit panning can take
place in the horizontal plane and check that line of sight with CT antenna does not
breach the deployment rules. The outdoor unit mounting pole is locally provided and
should be 38mm or 1.5" in diameter. The pole should be fixed according to the pole
manufacturers’ instructions.
Note: Leave adequate clearance around the outdoor unit assembly to allow for the
full adjustment range when aligning the outdoor unit.
4. Secure the outdoor unit radium to the mounting pole bracket using the four M6*50mm
hex head set screws, 6mm flat, and 6mm coiled washers as shown below. Some
outdoor units have the bracket factory fitted.