User's Manual
Installation
55
Mounting Outdoor Unit (vertical polarisation)
3. Attach the pole to the bracket as shown in the illustration above. Fully tighten onto
the pole.
4. Fix the pole to the bracket. The pole snaps into place and the bracket may need
easing slightly to allow the pole to pass over the raised dome, Place the coach bolt
through the bracket from the top so that the square shank locates into the square hole
in the bracket.
5. Rotate the outdoor unit to face in the general direction of the CT. Place the washer
faced self locking nut onto the bolt and tighten sufficiently to secure the pole in place.
The nut will be finally tightened when panning at the commissioning stage
Lightning Protection
1. When the outdoor unit is attached to two / three floor dwellings lightning protection
should not be needed. If the outdoor unit is situated in an exposed position i.e on the
top of a multi-storey building the outdoor unit should be grounded.
2. Run a stranded copper cable from the antenna to a protection earth point i.e building
earth halo or earth provided specifically for lightning protection. The earth connection
from the outdoor unit shall be a minimum of 10 AWG (6 mm2) copper wire in
accordance with UL 96 and 96A. The outdoor unit drop cable shall be run separately
from the earth cable and any cables carrying hazardous voltages.
3. Secure the cable to the pole using straps and cleats as required
4. Fit a 6mm lug to the cable at the antenna end. Attach to the pole mount bracket
using the lower right M6 set screw as shown in figure below.