User's Manual
605-0000-595 Subscriber Terminal Installation and Commissioning
50
Wall Mounted Outdoor Unit horizontal polarisation
6. Join the two halves of the bracket together using a bolt, spring washer, and plain
washer to top and bottom pivots.
7. Rotate the outdoor unit to face in the general direction of the CT. At this stage, only
finger tighten the pivot bolts.
Lightning Protection
1. When the outdoor unit is attached to two / three floor dwellings lightning protection
should not be needed. If the outdoor unit is situated in an exposed position i.e on the
top of a multi-storey building the outdoor unit should be grounded.
2. Run a stranded copper cable from the outdoor unit to a protection earth point i.e
building earth halo or earth provided specifically for lightning protection. The earth
connection from the antenna shall be a minimum of 10 AWG (6 mm2) copper wire in
accordance with UL 96 and 96A. The antenna drop cable shall be run separately from
the earth cable and any cables carrying hazardous voltages.
3. Secure the cable to the pole using straps and cleats as required
4. Fit a 6mm lug to the cable at the antenna end. Attach to the pole mount bracket using
the lower right M6 set screw as shown in figure below.