User's Manual
605-0000-595 Subscriber Terminal Installation and Commissioning
48
Outdoor Unit Wall Bracket Positioning and Securing
Securing Outdoor Unit Wall Bracket to wooden structure
1. Using the wall bracket as a template, mark the first hole position.
2. Drill a first hole pilot, 5mm diameter to a depth of 15mm (use a drilling depth gauge),
place the mounting bracket on the wall with the pivot hinge set for correct panning.
Screw the M8 coach bolt provided through the mounting bracket into the hole.
Tighten sufficiently to secure the bracket to the wall.
3. Using a spirit level, adjust the position of the wall bracket and mark the remaining 3
holes.
4. Drill the remaining pilot holes, 5mm diameter to a depth of 15mm, then fit the hex
head M8 coach bolts provided through the mounting bracket into the holes.
5. Tighten all the bolts sufficient to ensure a firm fixing to the wall.
Securing Outdoor Unit Wall Bracket to brick/block structure
1. Using the wall bracket as a template, mark the first hole position. Where the Outdoor
Unit is to be mounted to a brick built building, try to ensure that each hole coincides
with the middle of a brick and not the mortar course.
2. Drill the first hole, 8mm diameter to a depth of 45mm (use a drilling depth gauge),
place the mounting bracket on the wall and then fit the hex head M6 Dyna Bolt
provided through the mounting bracket into the hole. Tighten sufficiently to secure the
bracket to the wall.
3. Using a spirit level, adjust the position of the wall bracket and mark the remaining
three holes.
4. Drill the remaining holes, 8mm diameter to a depth of 45mm, then fit the hex head M6
Dyna Bolt provided through the mounting bracket into the hole.
5. Tighten all the bolts sufficient to ensure a firm fixing to the wall.
Fixed wall mounting bracket
1. Assembling arm and bracket