12. Fit the cable tray immediately above the AS4020 shelf. Fix the shelf with two
cross head screws and locking washers.
13. Connect the IDC end of the combiner monitor connecting lead (454-0010-134) to
the IDC connector in the cable assembly 454-0010-137 added in step 8.
14. Connect part no 454-0010-135 to the 26way high density D-type labeled 'Radio'
on the front panel of the AS4020
15. For additional shelves connect cables as shown in the AS4020 installation
diagrams and follow the steps above where applicable.
16. Use a straight connected Ethernet cables to connect the patch panel /router/ IP
network/ etc to the Management Port and Traffic Ports.
17. Replace the covers removed from the combiner shelf.
18. Attach the front cover to the shelf tray(s)
19. Replace the side panels on the rack and secure with four retaining screws.
The unit is now ready for commissioning.
For details of interface connections see AS4020 Interface Connections
Note if installing more than one shelf the same instructions apply as above but the
connections will differ see the accompanying diagrams.