Installation
59
120 ohm connection to CT modem shelf.
Connect the 2Mbit/s ports on the DDF to E5 slot 5 connectors on shelf interface
connections located on the modem shelf interface panel. If using protected mode connect
the other 2Mbit/s cables to E5 slot 9 connectors on the same panel.
Ensure that the respective 2Mbit/s ports have been configured on the DDF/Backhaul
Tie in cables as necessary using suitable cable ties, trim, leaving no sharp edges.