Fit the RJ45 adapter 303-1112-900 and secure to the Backplane using screws in the top and
bottom holes of the adapter.
RJ45 adapter 303-1112-900
b) T1 Cabling (Switch Link)
From the site survey, confirm the location of the Digital Distribution Frame (DDF) if a DDF is
to be used or the Switch if the T1 feeds are fed directs to the equipment. The length of T1
feeds should not exceed 100 metres.
Run the T1 cables from the AC shelf to the allocated positions on the DDF. In partial
equipped installations it may be appropriate to run enough cables to cater for a complete rack
of equipment. This reduces the need to disturb original installation when adding additional
equipment.
Feed the T1 cables through the top hole on the most convenient side of the rack, and down
the front of the rack.
Identify and label each cable at both ends as well as the DDF/Backhaul positions.
Terminate all cables with RJ45 connectors as shown above and fit RJ45 adapter to the D-
Type Plugs on the AC Interface Panel as shown above