User's Manual
Table Of Contents
- Installation
- Overview AS4000
- Overview AS4020
- Preparation
- Rack Installation
- AS4000 AC Rack Cabling and Wiring
- AS4000 CT Shelf Cabling and Wiring
- _
- Expansion Rack Cabling
- Setup and Test
- System Testing
- AS4000 AC Setup and Test
- Access Concentrator: Turn-Up and DC measurements
- Setting Up the Access Concentrator
- _
- Setting the TEI and Baud Rate for Netspan Connection
- Creating AC Shelf/Rack on Sitespan
- Setting up AC Rack and Shelf configuration
- Configure AC Cards
- Configure AC Shelf properties
- Check Boot Sequence
- Alarm and Status Indications (Test 3)
- Self Test (Test 4)
- Test CTU cabling to the DDF E1 Cards
- Test CTU cabling to the Distribution Frame (DDF) GR303 Cards.
- Test XTU cabling to the DDF
- Connecting the AC to the Network
- Connect E1s/T1s to the Switch or Cross-Connect at the DDF
- Access Concentrator Rack Commissioning Test Results
- AS4000 CT Setup and Test
- AS4020 CT Setup and Test
- _
- General
- Repair and Return Procedure
- Repair Charges
- Return & Repair Tag
- Packing and Shipment
- Glossary
- Index
Printed Documentation
176
Specifications
Central Terminal
The following tables provide technical specifications for the Central
Terminal.
PHYSICAL CHARACTERISTICS
CT Rack Dimensions, (without
brackets):
Full Height
Compact
Width 600mm 600mm
Height 2175mm 1500mm
Depth 300mm 300mm
Shipping Weight:
Rack Frame 60 kg
Air Inlets/Outlets 16.5 kg
Combiner Shelf 30 kg
Power Amp 4.5 kg (each)
LNA 1 kg Frequency Dependant
TX filter 1 kg Frequency Dependant
PSU 1.5 kg (each)
AS4020 Shelf 3.5kg (each)
ENVIRONMENTAL
Minimum Maximum
Operating Temperature
-5 C +45 C
Relative Humidity, non-condensing 0% 95%
Storage Temperature
-40 C 85 C