User's Manual
Table Of Contents
- Installation
- Overview AS4000
- Overview AS4020
- Preparation
- Rack Installation
- AS4000 AC Rack Cabling and Wiring
- AS4000 CT Shelf Cabling and Wiring
- _
- Expansion Rack Cabling
- Setup and Test
- System Testing
- AS4000 AC Setup and Test
- Access Concentrator: Turn-Up and DC measurements
- Setting Up the Access Concentrator
- _
- Setting the TEI and Baud Rate for Netspan Connection
- Creating AC Shelf/Rack on Sitespan
- Setting up AC Rack and Shelf configuration
- Configure AC Cards
- Configure AC Shelf properties
- Check Boot Sequence
- Alarm and Status Indications (Test 3)
- Self Test (Test 4)
- Test CTU cabling to the DDF E1 Cards
- Test CTU cabling to the Distribution Frame (DDF) GR303 Cards.
- Test XTU cabling to the DDF
- Connecting the AC to the Network
- Connect E1s/T1s to the Switch or Cross-Connect at the DDF
- Access Concentrator Rack Commissioning Test Results
- AS4000 CT Setup and Test
- AS4020 CT Setup and Test
- _
- General
- Repair and Return Procedure
- Repair Charges
- Return & Repair Tag
- Packing and Shipment
- Glossary
- Index
Setup and Test
131
Set Traffic/Management Ports
The traffic port connects to the Ethernet connecting to the internet service provider and the
management port connects to the Netspan server.
Enter the following parameters from the front panel of the AS4020. The values are
determined by the server that the network is connected to.
IP address = in the form xxx.xxx.xxx.xxx i.e 192.254.130.030
Subnet mask = in the form xxx.xxx.xxx.xxx i.e 255.255.000.000
Gateway address = may be used if management is on another network else set to
000.000.000.000
Broadcast Address = used for broadcasts and would usually be the network address
and mask so for the IP network above would be 195.254.255.255 but this information
should be provided by the network administrator.
Ethernet Rate. Set to the rate dictated by the network, if in doubt set to Auto
Duplex Mode