Setup and Test
123
Setting RX Sensitivity without DACU
Tools and equipment needed.
Item
Description Recommended Model Quantity
1 Digital Multimeter Fluke 77 1
2 ST Test Unit, SIU with Modified Antenna at
appropriate band
1
3 30dB Attenuators; 5W Mini Circuits: BN-N30W5 2
4 30dB Attenuators; 2W M/A-COM:2082 6044 30:2W 2
5 Two Way Power
Divider
Mini Circuits: ZAPD-4-S 1
6 50 ohm Termination
10W
Arra N9510 1
7 Adaptor; N-SMA Huber & Suhner 33N-SMA-50-1 1
8 Adaptor; N-SMA Huber & Suhner 31N-SMA-50-1 1
9 Huber & Suhner Sucoflex 104; 0.5m 2
10
Co-ax Cables
Huber & Suhner Sucoflex 104; 4.0m 1
11 Cable SMA-MCX Huber & Suhner 30-05918-10 1
12 RF Power Meter Marconi 6970 1
13 Power Sensor Marconi/RFI 6970&5 6932/900 1
RX Sensitivity (Test 6)
1. To set the receive sensitivity, first set up a test network for the band under test as
shown below. The figure below show the test equipment connected directly to the
outputs of the DIP/LNA and DIP/LNA2 as would be the case for systems without a
RFcoupler.