User's Manual
Table Of Contents
- Installation
- Overview AS4000
- Overview AS4020
- Preparation
- Rack Installation
- AS4000 AC Rack Cabling and Wiring
- AS4000 CT Shelf Cabling and Wiring
- _
- Expansion Rack Cabling
- Setup and Test
- System Testing
- AS4000 AC Setup and Test
- Access Concentrator: Turn-Up and DC measurements
- Setting Up the Access Concentrator
- _
- Setting the TEI and Baud Rate for Netspan Connection
- Creating AC Shelf/Rack on Sitespan
- Setting up AC Rack and Shelf configuration
- Configure AC Cards
- Configure AC Shelf properties
- Check Boot Sequence
- Alarm and Status Indications (Test 3)
- Self Test (Test 4)
- Test CTU cabling to the DDF E1 Cards
- Test CTU cabling to the Distribution Frame (DDF) GR303 Cards.
- Test XTU cabling to the DDF
- Connecting the AC to the Network
- Connect E1s/T1s to the Switch or Cross-Connect at the DDF
- Access Concentrator Rack Commissioning Test Results
- AS4000 CT Setup and Test
- AS4020 CT Setup and Test
- _
- General
- Repair and Return Procedure
- Repair Charges
- Return & Repair Tag
- Packing and Shipment
- Glossary
- Index
Printed Documentation
120
Procedure in case of card boot-up failure
Procedure in case of card boot-up failure
If the cards inserted into the shelf do not boot-up, the top red LED on the card will be either
continuously ON or FLASHING. The following steps should be followed:
1. Check cards are properly inserted into the shelf, in the correct positions
2. Reset the SC card using Netspan/Sitespan, under the card view.
3. The cards boot-up. If the cards do not boot-up try and reset the shelf backplane
configuration. Download the SetTUinv.txt to the SC. Ensure they are available before
continuing.
4. Disconnect Netpan from the shelf containing cards that will not boot-up.
5. Connect the LAT cable to the SC card
6. Send the text files for the correct shelf, one after another using Terminal.
7. Once completed, type the following:
TI 118
EA 118:0/119:0
ES 0
8. Wait 2 – 3 minutes for the process to complete.
9. Reset the SC by shorting Pins 2 & 3
10. Wait for 3 minutes: After 3 minutes the Shelf Controller has a green LED ON
, and all
the other cards have FLASHING red LEDs
11. Re-Connect Netspan /Sitespan
12. The cards on the shelf boot-up. If the cards do not boot-up, then it is likely that one of
the cards is faulty. Try replacing one of the cards and starting the procedure again.