Procedure in case of card boot-up failure
Procedure in case of card boot-up failure
If the cards inserted into the shelf do not boot-up, the top red LED on the card will be either
continuously ON or FLASHING. The following steps should be followed:
1. Check cards are properly inserted into the shelf, in the correct positions
2. Reset the SC card using Netspan/Sitespan, under the card view.
3. The cards boot-up. If the cards do not boot-up try and reset the shelf backplane
configuration. Download the SetTUinv.txt to the SC. Ensure they are available before
continuing.
4. Disconnect Netpan from the shelf containing cards that will not boot-up.
5. Connect the LAT cable to the SC card
6. Send the text files for the correct shelf, one after another using Terminal.
7. Once completed, type the following:
TI 118
EA 118:0/119:0
ES 0
8. Wait 2 3 minutes for the process to complete.
9. Reset the SC by shorting Pins 2 & 3
10. Wait for 3 minutes: After 3 minutes the Shelf Controller has a green LED ON
, and all
the other cards have FLASHING red LEDs
11. Re-Connect Netspan /Sitespan
12. The cards on the shelf boot-up. If the cards do not boot-up, then it is likely that one of
the cards is faulty. Try replacing one of the cards and starting the procedure again.