User's Manual
Table Of Contents
- Installation
- Overview AS4000
- Overview AS4020
- Preparation
- Rack Installation
- AS4000 AC Rack Cabling and Wiring
- AS4000 CT Shelf Cabling and Wiring
- _
- Expansion Rack Cabling
- Setup and Test
- System Testing
- AS4000 AC Setup and Test
- Access Concentrator: Turn-Up and DC measurements
- Setting Up the Access Concentrator
- _
- Setting the TEI and Baud Rate for Netspan Connection
- Creating AC Shelf/Rack on Sitespan
- Setting up AC Rack and Shelf configuration
- Configure AC Cards
- Configure AC Shelf properties
- Check Boot Sequence
- Alarm and Status Indications (Test 3)
- Self Test (Test 4)
- Test CTU cabling to the DDF E1 Cards
- Test CTU cabling to the Distribution Frame (DDF) GR303 Cards.
- Test XTU cabling to the DDF
- Connecting the AC to the Network
- Connect E1s/T1s to the Switch or Cross-Connect at the DDF
- Access Concentrator Rack Commissioning Test Results
- AS4000 CT Setup and Test
- AS4020 CT Setup and Test
- _
- General
- Repair and Return Procedure
- Repair Charges
- Return & Repair Tag
- Packing and Shipment
- Glossary
- Index
Printed Documentation
96
3. Select the site.
4. Enter name. The name must be unique within the network or an error message is
displayed and the shelf is not created.
5. Click OK to add shelf to the database.
6. The shelf is displayed on the tree view
7. Move mouse pointer to the shelf icon and right click. Select configure from the menu.
8. Continue with 'Setting up AC Rack and Shelf Configuration' below
Setting up AC Rack and Shelf configuration
1. Click right mouse button over AUX card position 4 select and create a CTU card.
2. Create additional CTU cards in slots 5 and 6 if required.
3. Position mouse over CTU card position, click right mouse button and select Airspan
CTU Properties
4. Set up the CTU properties as detailed in the Netspan Section
5. Repeat for other CTU cards.
6. Click OK
Assign Access Concentrator Card Slots
1. Click right mouse button over AUX card positions 7-17 to create other AUX cards as
required (XTUs RTU and PTU and Compression Unit.
2. Select the card type to be created.
3. Repeat steps 1 to 3 for all cards to be installed in the shelf.
Configure AC Cards
1. For details on configuring the cards see the relevant topic in the Netspan section of
this manual
Configure AC Shelf properties
1. Make sure the SC software is at the correct release, and all cards can be seen on the
AC Shelf equipment view. If required download the appropriate software by following
the software download procedure (see Software Download
)
2. Re-boot the Shelf by clicking the Reset Shelf button on the shelf controller view.