AS4000 RELEASE 3: 2Mbit/s / CABLING
1. 2Mbit/s Cabling 75 Coax
From the site survey, confirm the location of the Digital Distribution Frame (DDF).
The length of 2Mbit/s feeds from the rack to the DDF should not exceed 250 metres
Note: This must be a SELV port of an EN 60950 approved product.
Run the 2Mbit/s co-axial cables from the modem shelf to the allocated positions on the
DDF. (Two cables per shelf). In partial equipped installations it may be appropriate to
run enough cables to cater for a complete rack of equipment. This reduces the need to
disturb original installation when adding additional equipment.
Feed the cables through the top of the rack , out through the hole in the right hand side
of the top shelf and down the front of the rack.
Fit Ferrites to each cable at the point of entry to the shelf. Secure a tie wrap each side
of the ferrite to keep it in place. See Figure 15.
Identify and label each cable at both ends as well as the DDF positions.
Terminate all cables with the appropriate Co-ax connector. (BNC for 2002 or Type 43
for 3002 cable).