CONFIGURING THE ACCESS CONCENTRATOR
STEP PROCEDURE
1. Configure the Access Concentrator
1. Select the Access Concentrator to be configured.
2. Connect the Access Concentrator shelf to Sitespan (ensuring the cable is connected to
selected com port)
E1 IN
E1 OUT
E2 IN
E2 OUT
SITESPAN !
SITESPAN 2
SLOT 4
Figure 19. Access Concentrator Shelf Backplane
3. Re-boot the Shelf Controller card by ‘Hotplugging.
4. SC card boots-up and displays the following LED sequence:
a) Red & green LEDs both ON
b) All LEDs OFF
c) Green LED FLASHING
d) Green LED ON
e) The red LED temporarily comes ON
5. All the cards on the shelf now boot-up.
6. The TU cards l display the following LED sequence:
Note: The boot-up procedure for these cards takes approximately 15minutes.
d) Red LED, amber LEDs & green surface mount LEDs all ON. Green LED
FLASHING