CONFIGURE AS4000 DA ACCESS CONCENTRATOR SHELF
XTU CAS CARD
Use this procedure to set-up the XTU CAS card on the AS4000 DA Access Concentrator
Shelf. The shelf view, or an object list containing the card should be displayed at the start of
this procedure. See GSI-017 Selecting Views.
STEP PROCEDURE
1. Select the Card to be set, click the right mouse button and select from the drop menu select
the Airspan DA XTU(CAS)View.
2. With Shelf view displayed. Position mouse over the CAS Card position to insert card,
click right mouse button and select Airspan CAS Properties. Click left mouse button in
the box alongside each E1 link provisioned to the Switch.. Note: If the box remains
unchecked, the card still functions, but the card alarms are not reported by Sitespan.
3. Set the impedance of each link. If special signalling features are required, click the
Configure button and enter the parameters. Repeat for other CAS cards.