STEP PROCEDURE
Observe full ESD precautions.
1. Press Receive Attention on the modem shelf cover to suppress alarm.
2. Use a DMM to check the output of the PSU at the voltage test output on the PSU
front panel. The output should measure 13.5V ±100mV
3. If the output is present but an alarm still exists the monitor circuit within the PSU is
likely to be faulty. Change the PSU. The PSUs operate in redundant mode.
Removing a PSU will not affect the operation of the rack. Use the ring pull at the
front of the PSU to assist with removal. Replace the card ensuring that the PSU is
located within the shelf card guides.
4. If there is no output change the PSU.
5. Use a DMM to check the output of the new PSU at the voltage test output on the
PSU front panel. The output should measure 13.5V ±100mV
6. If after changing the PSU alarm still exists then check that the voltage is present on
the input to the PSU as it is most likely that there is a backplane fault. If the
backplane is faulty change the Combiner Shelf.
STOP. THIS PROCEDURE HAS BEEN COMPLETED.