User Manual

AS4000 Operations and Maintenance
Section
605-0000-431
4
. Issue 1.6. Date3/2/99
DLP-011
Page 38 of 44 © Copyright Airspan Communications Corporation 1999
POWER AMPLIFIER (PA) ALARMS
Alarm Indications
AS8100 (Sitespan) : Combiner:PowerAmp(N):FRU Fail
Rack: Major/Prompt
Modem Shelf Alarm Panel: Fault Alarm
Card Alarm: PA Fail
Probable Cause
Faulty PA module
Consequences:
Loss of service to all users connected to associated modem shelf.
Maintenance Clear Strategy
Change PA
STEP PROCEDURE
Observe full ESD precautions.
1. Press Receive Attention on the modem shelf covers to suppress alarm.
2. Change PA module. Each PA Unit contains two Power Amplifiers, when the Power
Amplifier is removed the traffic from two modem shelves will be disrupted. Use a
screwdriver to release the screw twist retainers from the top and bottom of the PA (half a
turn is sufficient). Use the handles to ease the card from the backplane connector. Use
caution when handling the PA as the unit may be hot. Replace the card ensuring that the
card is located within the shelf card guides. PA2 is inserted inverted. Use the extractor
lever to ensure that the card locates properly. Use a screwdriver to secure the screw twist
retainers at the top and bottom of the PA.
3. The PA will be set to the values contained in the RF card and will adjust its power output
using the control loop.
HOT
HOT
Amber OK
Red PA1 Fail
Red PA2 Fail