User Manual

AS4000 Operations and Maintenance
Section
605-0000-431
4
. Issue 1.6. Date3/2/99
DLP-008
Page 31 of 44 © Copyright Airspan Communications Corporation 1999
MONITOR CARD (MON) ALARMS
Alarm Indications
AS8100 (Sitespan) : Monitor:FRU Fail
Rack: Major/Prompt
Modem Shelf Alarm Panel: Fault Alarm
Card Alarm: Monitor Card Fail
Probable Cause
a). Card failure
b). Monitor Card PSU failure
Consequences
Messages/ alarms will not be passed from the monitor card to the
SC cards.
Maintenance Clear Strategy
Change Monitor Card
STEP PROCEDURE
Observe full ESD precautions.
1. Press Receive Attention on the modem shelf cover to suppress alarm.
2. Change Monitor card. Use the board extractor lever to remove the card from the shelf.
Replace the card ensuring that the card is located within the shelf card guides. Use the
extractor lever to ensure that the card locates properly. Observe full anti-static
precautions.
STOP. THIS PROCEDURE HAS BEEN COMPLETED.
Amber Power/Module
Red Monitor Card Fail