ANALOGUE UNIT (AU) ALARMS
Alarm Indications
AS8100 (Sitespan) : a) ‘AnalogueCard: FRU Fail’
b) ‘AnalogueCard: PSU Fail’
Note: Sitespan views the RF and Analogue cards as one object , the
LED indication will show which of the cards has failed.
Rack: Major/Prompt
Modem Shelf Alarm Panel: Fault Alarm
Card Alarm: AU Fail
When the AU card fails, the SC will send ‘FRU failure’ messages to
the Sitespan to indicate each of its shelf elements is failing to
respond. In this situation, the engineer can assume the AU has failed
(it is very unlikely that these messages will occur together).
Probable Cause
a) Card Fail
b) AU PSU Fail
Note: If both the amber and red LEDs are lit then it is probable that
the RF Card has failed.
Consequences
a) Card Fail: Failure of service for all subscribers.
b) AU PSU Fail: None as Shelf Controller PSU provides back-up power supply.
Note: The Analogue Card is not ‘hot plugable’ and after replacing it the modem shelf will
need to be power cycled by disconnecting and re-connecting power to the shelf.