Maintenance Clear Strategy
Loss of comms with Sitespan
Start
No
Yes
Are
other shelves
at the same CT
still operational
?
Possible faults
a) Complete power fail at CT
b) PC Internal fault
c) Multiple disconnections of PC
to shelf controller cables
Possible faults
a) SC Card failure
b) PC interface fault
c) Disconnection of PC to
shelf controller cable
d) Power fail to shelf
Continue fault diagnosis
at CT to clear fault
STEP PROCEDURE
Observe full ESD precautions.
1. Using Sitespan :
Check to see if there are other ‘Loss of Comms’ messages
a) From other CTs. Most likely AS8100 (Sitespan) Interface problem.
b) From other shelves on the same CT. Probably a port fault or complete power
failure to the rack.
2. Further faulting will need to be at the CT site.
3. Using the Flow Chart above decide on possible faults.
4. Check the items listed as possible faults and change/repair as required.
STOP. THIS PROCEDURE HAS BEEN COMPLETED.