CHANGING THE TYPE 2 PSU
The Type 2 PSU (ACPSU) consists of an AC PSU Unit with standby batteries and
generates power fail alarms that are passed to the CT.
Tools and equipment needed
ITEM DESCRIPTION SIZE
01 Snake Eye Screwdriver
02 Screwdriver Pozidrive No 1 x 75mm
03 Screwdriver Pozidrive No 2 x 199mm
04 Screwdriver Pozidrive No 3 x 150mm
05 Screwdriver Flat Blade 3mm x 100mm
06 Digital Multimeter Fluke 77 or similar
07 Test Telephone
STEP PROCEDURE
1. Unplug the PSU from the AC supply.
2. Unscrew and remove the PSU front cover using a Snake-eye screwdriver.
3. Disconnect the drop cable and the NTU wiring.
4. Remove the faulty PSU by unscrewing the No 8 x 50mm screws that secure the unit to the
wall.
5. Secure the new PSU squarely in position using the No 8 x 50mm screws (Part No 174-
0815-002) and cup washers (Part No 192-0080-230) previously securing the faulty power
unit.
6. Reconnect the drop cable and NTU wiring to the blocks TB1 and TB2. For connector
detail see DLP-024 (Replacing the drop cable)
7. Plug the AC supply cord into the IEC connector on the PSU and secure with retaining
clip.
8. Connect the batteries to the PSU. Care should be taken when handling lead acid batteries
to avoid dropping or short circuiting them. Disposal should be in line with local codes.
Batteries may explode if put into a fire. Install the batteries in the PSU first, then connect
them taking care to observe correct polarity. Connect the blue lead first to connect them
together, then connect the red lead to the +ve terminal and the black lead to the -ve
terminal.