CHANGING THE TYPE 1 PSU.
The Type 1 PSU consists of an AC Brick Power Unit and a Junction Box.
The Type 1 PSU exists in both 24V and 30V versions ensure that if changing the PSU on
a ST-D128 installation that a 30V Type 1 PSU is used.
STEP PROCEDURE
1. PSU (Type 1) Connection to the Junction Box
1. The PSU is free standing and should be placed near to the Junction Box in a non-
hazardous location.
2. Cut the 3 pin socket off the DC output cable and trim and prepare ends for connection to
the Junction Box as shown in Table 7 below.
Terminal Colour Description
4 Red V+ (24V)
5 Green Earth/Screen
6 Black 0V
Table 7. PSU (Type 1) to Junction Box Connections
2. AC Power Cord Installation
1. Use a supply cord fitted with a mains plug in accordance with local requirements.
2. Plug the AC supply cord into the IEC connector on the PSU(Type 1).