User Manual
AS4000 Operations and Maintenance
Section
605-0000-431
6
. Issue 1.6. Date3/2/99
DLP-017
Page 25 of 60 © Copyright Airspan Communications Corporation 1999
PROGRAMMING THE ST-V2 CRU
TYPE 2 PSU USING A TELEPHONE
The following procedure will have to be completed before placing the ST into
service.
Tools and equipment required
ITEM DESCRIPTION TYPE
03 Snake Eye Screwdriver
09 Test Telephone DTMF or LD
STEP PROCEDURE
ST Programming
1. Remove the cover from the ACPSU
2. Connect an MF or LD type telephone to the NTU.
3. Each CRU is initialised by entering a unique code. These codes are entered
using the Telephone and should be provided by the RF planning office on a
form similar to that shown in Table 2.
RF *
2/3 digits
PN
1 digit
RW
2 digits
Identity
6 digits
Check N
o
.
1 digit
Remote site
location
1 0 6 1 0 1 000000 7 CRU1
*Note: Older CRUs will have a 2 digit RF code. Newer CRUs will have a
3 digit RF code.
Table 2 CRU Programming Information
4. Initialisation
To programme the CRU, depress the reset switch, SW4(S1 in early versions),
in the AC PSU for approximately 3 seconds. LED D8(D1 in early versions) will
begin flashing to indicate the CRU initialising and self test sequence. After
approximately 10sec, the CRU initialising and self test sequence will be
complete and the LED will be extinguished. LED D9(D1 in early versions)
will still be illuminated.
Should the above sequence not be successfully executed, replace the faulty
CRU.