User Manual
AS4000 Operations and Maintenance
Section
605-0000-431
6
. Issue 1.6. Date3/2/99
DLP-016
Page 24 of 60 © Copyright Airspan Communications Corporation 1999
3. Turn the securing nut on the drop cable anti-clockwise to disconnect the drop cable from
the CRU.
4. Fully unscrew the hinge bolts to remove the faulty CRU. Ensure that the CRU is fully
supported when removing the bolts.
5. Secure New CRU with the hinge bolts. Do not fully tighten the bolts at this time.
6. Connect the drop cable to the CRU. Turn the securing nut on the drop cable fully
clockwise.
7. Align the CRU to the alignment mark made in Step 1. Tighten the bolts
8. Go to DLP-017 for instructions on programming the CRU from a Telephone (V2 Type 2
PSU only) or DLP-018/19 for instructions on programming the CRU using STMON and
then to DLP-020 to setup the CRU for service.
STOP. THIS PROCEDURE HAS BEEN COMPLETED.