User Manual
AS4000 Operations and Maintenance
Section
605-0000-431
6
. Issue 1.6. Date3/2/99
DLP-015
Page 21 of 60 © Copyright Airspan Communications Corporation 1999
13. If any errors occur the LCU will stop the level control operation and set the
operation mode to Idle automatically. When this occurs view the Error Menu
for the source of this error.
Error SH:1 0E-
Comms * Conv 0--
Sh Id Det ---
CRC Modem ---
Communications time-out error
Incorrect shelf identifier in the
received data packet
Incorrect CRC checksum in the
received data packet
Failed to converge within 15 mins
(applicable only to poll modes)
RF failure in LCU
Failed to enable the modem
associated with the RW
14. Key F6 twice Select Configuration Set-up.
15. Select Mode Select.
16. Set to the required polling interval 1 hour, 1 day, or Idle. If the shelf is left in
continuous mode it will revert to idle mode after 1 hour.
Mode SH:1 0E-
1-T
Mode:********** 0--
0--
Possible Modes
Idle
None (shelf not present)
Continuous
Hour
Day
17. Key F5 to return to the Shelf Selection Menu
STOP. THIS PROCEDURE HAS BEEN COMPLETED.