User Manual
AS4000 Central Terminal
Installation and Commissioning
DLP 011
605-0000-452
Issue 1.3dr Date 7/02/00
Page 4 of 6
STEP PROCEDURE
2. Rx Sensitivity (Test 6)
1. To set the receive sensitivity, first set up a test network for the Band under test as shown in
Figure 34 and Figure 35 below. The Figures below show the test equipment connected
directly to the outputs of the DIP/LNA and TX filter as would be the case for systems
without coupler.
Power
Meter
Test
ST
(2.0-2.3GHz)
(2.3-2.5GHz)
(3.0-3.4GHz)
CT Rack
3
1 2
30dB
30dB
30dB 30dB
2:1
Splitter
2:1
Splitter
2:1
Splitter
SMA-N
RF Sensor
N-SMA
11dB
Variable *
* Set variable attenuator
to a nominal value of 5dB
Termination
TX 1 & 2
RX 1, 2, 3, 4
TX 3 & 4
A
B
C
Screened Box
Figure 34. Test Set-up 2.0-2.3GHz, 3.4-3.6GHz, and 2.3-2.5GHz Bands.