User Manual

AS4000 Central Terminal
Installation and Commissioning
DLP 009
605-0000-452
Issue 1.3dr Date 7/02/00
Page 10 of 10
IMPORTANT NOTE: An RW code can only be placed Out of Service if it is
currently not in use by the system (See GRD). Before proceeding, it is important that
the DTU card view is checked, to ensure that the RW code is in the desired state.
19. In the RW management window place the mouse pointer over the IS for RW 1 click
left mouse button until OOS is selected. Repeat for RW2 and RW3 to prepare for
commissioning. Once RW codes have been reserved for Test links, the ST can be
programmed in the usual method, although the RW channels that the 10kbit/s and
160kbit/s links are acquired on, must be the same as the ones set-up in the DTU card
properties (i.e. NOT RW 15!).
STOP. THIS PROCEDURE HAS BEEN COMPLETED.