User Manual

AS4000 Central Terminal
Installation and Commissioning
DLP 008
605-0000-452
Issue 1.3dr Date 7/02/00
Page 14 of 14
6.4. V5.1
1. With Shelf view displayed. Position mouse over the V5.1 Card (if V5.1 card installed)
position to insert card, click right mouse button and select Airspan V5.1 Properties. Click
left mouse button on each E1 linkTab provisioned to the Switch. Enable Channel, set the
impedance of each link. Enter Interface ID and Variant Number (these must match those
provided at the switch). Select the service type (PSTN, ISDN or Mixed).
A) PSTN. Select the Timeslot 15,16 or 31 for signalling Each PSTN signalling Time Slot
must be allocated a L3 address Number (these must also match those provided at the
switch). Select each time slot in turn and enter the L3 number. If special signalling
features are required, click the Configure button and enter the parameters. Repeat for
other V5.1 cards.
B) ISDN Set the port and EF addresses Number (these must match those provided at the
switch). The S, P and F type Cpaths can use the sane timeslot Common Channel
signalling Path as the PSTN or may use a different time slot (these must match those
provided at the switch).
STOP. THIS PROCEDURE HAS BEEN COMPLETED.